Type 3IL with air sensor or
floor sensor
TSSHC-3IL is an electronic heating thermostat designed to be installed in a
standard single gang electrical box and requires no maintenance.
A LED
illuminates to indicate call" for heating, this also aids in system
testing. An ON/OFF selector switch on the front of the cover makes
system operation extremely simple.
PRODUCT LINE
| TSSHC-3IL with 16A relay switch, °F |
|
240 V supply ( -2 )
|
|
TSSHC-3IL-2FS UDF with floor sensor
|
| TSSHC-3IL-2
UDF with built-in sensor |
| 120 V supply ( -4 ) |
| TSSHC-3IL-4FS UDF wtth floor sensor |
| TSSHC-3IL-4 UDF with built-in sensor |
| 24V ( -24 ) |
| TSSHC-3IL-24FSF UDF with floor sensor |
| TSSHC-3IL-24 UDF with built-in sensor |
| |
| TSSHC-3IL with 16A relay switch, °C |
| 240 V supply |
| TSSHC-3IL-2CFS UDC with floor sensor |
| TSSHC-3IL-2C UDC with built-in sensor |
| 24 V supply |
| TSSHC-3IL-24CFS UDC with floor sensor |
| TSSHC-3IL-24C UDC with built-in sensor |
APPROVALS (only 120 Vac and 240 only)
3IL thermostats are UL and cUL Listed and meet UL8730-1 and
UL8730-2-9 standards for temperature indicating and regulating
equipment.
WARNING
The system may not be energized unless the system is installed
according to this installation and the installation meets all applicable
codes. Warranty is void if not installated according to this
instruction and proper procedure.
TECHNICAL DATA
Power supply (model dependent)
...........................24, 120 and 240 Vac ±1 0% , 60 Hz
Output relay, SPST...............................................16A
Built-in switch.............................................2
pole,16A
Ambient operating temperature......32-122°F (0-50°C)
Scale limitation.........................minimum and maximum
Scale range.................................50-122°F (10-60°C)
Temperature setback................................not available
On/Off differential...................................0.7°F 80.4°C
Enclosure.............................................................IP20
Dimensions(HXWXD).........................4.5"X3.3"X2.0"
..................................................... (1 15X84X50 mm)
FLOOR SENSOR INSTALLATION (where applicable)
The sensor shall be mounted in a conduit which should be sealed and
placed as high as possible in the concrete, etc. The sensor is UL and
cUL approved regarding the isolation test. The sensor wiring may be
extended up to 150' (50 m) using 18 gauge wire and the wiring resistance
shall not exceed 20 ohms. Sensor wires must be kept in a separate
conduit, away from all other wiring. The sensor and wires must be
protected from damage during the installation. If shielded wire is used,
it must not be grounded but connected to terminal 6 on the thermostat.
ERROR DETECTION (floor sensor model only) The 3IL has built-in error
detection which will de-energize the heating circuit if the sensor is
damaged or if it detects an open or shorted sensor circuit.
CAUTION!
Disconnect all electrical power prior to installing or servicing this
unit.
|
|
THERMOSTAT INSTALLATION (fig. 1-3)
1 . Remove thermostat knob, noting the position (A).
2. Loosen screw to remove frame and cover (B).
3. Attach wiring from the rear of the thermostat according to the
wiring diagram (fig. ???)
4. The thermostat is mounted in a single gang electrical box -
re-install frame and cover - re-install the knob in the proper position
TEMPERATURE SETTING/ADJUSTMENT
Adjust the temperature knob to the desired room or floor temperature,
if after a few days you find the temperature to be different from the
setting, adjustment can be made as follows: Measure the room temperature
with thermometer, remove the knob without rotating it, then reposition
the knob according to the measured temperature on the scale and
re-install it.
MAXIMUM/MINIMUM TEMPERATURE LIMITATIONS
Behind the knob there are red and blue locking rings held in position
by a screw. To set the limitations, loosen the screw (C) and adjust the
red limit ring to the desired maximum, set the blue ring to the desired
minimum temperature, then retighten the screw. The knob must be
reinstalled exactly as it was removed. |