Bid Specifications:

The ENERJOY® radiant heating panel shall be constructed of insulated Solid State Heating element. The element shall be backed with one-inch thick, high density, odorless fiberglass board, faced with a white finely textured aluminum face and framed in aluminum. Panels shall reach the full surface temperature in five minutes. Radiant output shall be 95% of input energy. Panels shall be listed under UL Standard 2021 – Fixed and Location-Dedicated Electric Room Heaters. Panel shall meet or exceed FHA/HUD Minimum Property Standards.

ENERJOY I Radiant Peopleheaters®


Contents:


ENERJOY Picture

enerjoy I Panel        

               ENERJOY Radiant Peopleheaters

Back to Top


Key Features

ENERJOY PEOPLEHEATERS® Specifications requirements:

Nominal sizes: 1’ increments up to 2’ in width and 8’ in length.

Models: RP-(rear wired); RPD- (surface wired).

Voltages: -1 (277v), -2 (240v), -3 (208v), -4 (120v).

Nominal Wattage: 50 Watts per square foot.

Radiant Output: 95% of input power.

Extension Ring: 2 1/8"x 4"x 1 ½" (such as Thepitt #592)

Finish: 1) Finely Textured Ceiling White, 2) Matte White (flat), 3) Appliance White (glossy), 4) Chocolate Bronze (flat brown)

Back to Top


Dimensions

Back to Top


Installation

INSTALLTION of the multi-sized panels is as easy as an electric light fixture – mounted on the surface, flush, placed in a suspended ceiling grid, or freely suspended. Painting, overspraying with water base acoustical material, or framing creates the desired aesthetic effect. Do no operate until dry.

Penetrable Surface Mounting (sheetrock) (Fig. 1)-(check for bag of hole plugs)

  1. Insure adequate clearance hole in center for module connection box.
  2. Install connection box to back of module using the prepositioned screws.
  3. Connect the power supply conductors to the module leads in the connection box.
  4. Position on ceiling, holding module in place.
  5. Punch or drill holes into the ceiling to provide a hole for the screw/anchor assembly, or mark holes for drill.  The frame mounting holes are designed to accept #6 -1 ¾” Pan head screws.
  6. Insert installer provided screw/anchor assembly into the ceiling, and tighten into place. Insert plastic caps to close frame screw holes.

T-Bar Mounting (Fig. 2)

  1. Install connection box to back of module using the two prepositioned screws.
  2. Lay the module carefully onto the T-Bar grid and secure with installer provided hold-down clips if necessary.
  3. Connect the power supply conductors to the module leads in the module connection box.

This is a description of a major benefit of using the product.

Inpenetrable Surface Mounting - RPD model (Concrete) (Fig. 3)

back to Top


PEOPLEHEATER® OPERATION TEST

Each panel has been individually checked at the factory. However each panel should be field checked by measuring cold resistance for confirmation with label wattage. After panel installation, the entire circuit should be tested, to check the on-sight electrical work. Two methods of testing will be discussed in the following paragraphs.

Full Power Available - Apply rated voltage to the heater load circuit. Branch loads are to be read with a suitable amp meter. The amp meter value should be the same as that calculated for the heating load and, if the values agree, all panels are operating. If the values do not agree, installation should be re-checked. For physical check without a meter, it is only necessary to feel the panels. If they are warm but can only be touched for a few seconds, they are working.

Without Power Available - This check of the panel installation requires the use and knowledge of an ohmmeter. A resistance measurement is taken at the load circuit, with all other circuits isolated. This will give the total resistance of the heater load. Knowing the total heater load of the panel in watts and the heater rated voltage, a simple calculation will give the same values as that read on the ohm meter. (The same test procedure applies of an individual panel)  Example: For a branch circuit of 1500 watts and panel rated voltage of 240, the resistance will be 38.4 ohms:

Text Box: 240 x 240 1500
Text Box: = 38.4 ohms




Back to Top


Specifications

All sizes also available in 208 and 277 volt     (other sizes and wattages available)
Model No. Voltage Watts BTUH Amperage Size Weight(lbs.)
Under Desk Heaters
12UDH-4 120 100 341 0.8 11¾" x 23¾" x 1" 3
22UDH-4 120 200 683 1.7 24¼" x 23¾ x 1" 3
Radiant Ceiling Panels                                   NOTE: All Panel Frames have mounting holes except T-BAR
22RP-2 240 200 682 0.8 24¼" x 23¾ x 1" 6
22RP-4 120 200 682 1.7 24¼" x 23¾ x 1" 6
22RP-2or4TBar 120or240 200 682 0.8 or 1.7 23¾" x 23¾ x 1" 6
23RP-2 240 300 1024 1.3 24¼" x 35¾ x 1" 8
23RP-4 120 300 1024 2.5 24¼" x 35¾ x 1" 8
24RP-2 240 400 1365 1.7 24¼" x 47¾ x 1" 11
24RP-4 120 400 1365 3.3 24¼" x 47¾ x 1" 11
24RP-2or4TBar 120or240 400 1365 1.7 or 3.3 23¾" x 47¾ x 1" 11
24RPH-2 or 4 120 or 240 500 1706 2.1 or 4.2 24¼" x 47¾ x 1" 11
25RP-2 240 500 1706 2.1 24¼" x 59¾ x 1" 13
25RP-4 120 500 1706 4.2 24¼" x 59¾ x 1" 13
26RP-2 240 600 2047 2.5 24¼" x 68¾ x 1" 15
26RPH-2 240 750 2560 3.1 24¼"x 68¾" x 1" 15
26RP-4 120 600 2047 5.0 24¼" x 68¾" x 1" 15
27RP-2 240 700 2388 2.9 24¼" x 83¾ x 1" 17
27RP-4 120 700 2388 5.8 24¼" x 83¾ x 1" 17
28RP-2 240 800 2730 3.3 24¼" x 95¾ x 1" 19
28RPH-2 240 1000 3413 4.2 24¼" x 95¾ x 1" 19
28RP-4 120 800 2730 6.7 24¼" x 95¾ x 1" 19
Bathroom Fan/light/nightlight package - complete: includes Decora switch/cover & thermostat
22RPFL-2 or 4 240 or 120 200 682 0.8/1.7 24¼" x 35¾" x 1" 7+25
23RPFL-2 or 4 240 or 120 300 1024 1.2/2.5 24¼" x 47¾" x 1" 9+25
24RPFL-2 or 4 240 or 120 400 1365 1.7/3.3 24¼" x 59¾" x 1" 12+25
25RPFL-2 or 4 240 or 120 500 1720 2.1/4.2 24¼" x 68¾" x 1" 14+25
26RPFL-2 or 4 240 or 120 600 2082 2.5/5.0 24¼" x 83¾" x 1" 17+25
27RPFL-2 or 4 240 or 120 700 2388 2.9/5.8 24¼" x 95¾" x 1" 19+25
ENERJOY THERMOSTATS
TSSHC-1 ALL LineVolt/Bimetal White 2¾" x 4½ x 1¾" 1
TSSHC-1P 120or240 LV-Prog. - 7-day/24hr Beige 2¾" x 4½ x 1¾" 1
TSSHC-1LV 24 Low volt non-mercury Beige 2¾" x 4½ x 1½" 1
TSSHC-12S ALL 2 Circuit, 2 Stage  line v. Beige 2 1/3" x 4½ x 1¾" 1
TSSHC-2H ALL Hydraulic Line Voltage  Beige 2¾" x 4½ x 1½" 1
TSSHC-2D (1) ALL Air Diaphragm Line V. White 2¾" x 4½ x 1¾" 1
TSSHC-3D 120or240 Digital Line Voltage Ivory 3¼" x 6¾" x 2¾" 1
TSSHC-3DP (2) 120 + 240 LV Digital Progammable  Ivory 5" x 5" x 1¾" 1
TSSHC-3DP 240 LV Digital Progammable Ivory 3" x 5" x 1 ¾ " 1
TSSHC-3BC 240 LV Programmable Bulb/Cap Ivory 2¾" x 4½ x 1½" 1
TSSHC-3ILAS (3) 120or240 LV Electronic White 3¼" x 4½" x 1¾" 1
TSSHC-3ILRS (3) 120or240 LV Electronic White 3¼" x 4½" x 1¾" 1
(1) Range stops, Locking cover, Thermometer, All Thermostats fit single gang Electrical Box
(2) Proportional Control Feature
(3) Range stops and Indicator Light
 


Back to Top


SSHC, Inc.
Copyright © 1998-2003 SSHC, Inc. All rights reserved.
Information in this document is subject to change without notice.


Characteristics of Radiant Heat | Quick System Sizing | Thermostats |
ENERJOY I - Specs | Comparison of Enerjoy I & II |