Bid Specifications:
The ENERJOY® radiant heating panel shall be constructed of insulated Solid State Heating element. The element shall be backed with one-inch thick, high density, odorless fiberglass board, faced with a white finely textured aluminum face and framed in aluminum. Panels shall reach the full surface temperature in five minutes. Radiant output shall be 95% of input energy. Panels shall be listed under UL Standard 2021 Fixed and Location-Dedicated Electric Room Heaters. Panel shall meet or exceed FHA/HUD Minimum Property Standards.

ENERJOY Radiant Peopleheaters
ENERJOY PEOPLEHEATERS® Specifications requirements:
Nominal sizes: 1 increments up to 2 in width and 8 in length.
Models: RP-(rear wired); RPD- (surface wired).
Voltages: -1 (277v), -2 (240v), -3 (208v), -4 (120v).
Nominal Wattage: 50 Watts per square foot.
Radiant Output: 95% of input power.
Extension Ring: 2 1/8"x 4"x 1 ½" (such as Thepitt #592)
Finish: 1) Finely Textured Ceiling White, 2) Matte White (flat), 3) Appliance White (glossy), 4) Chocolate Bronze (flat brown)


INSTALLTION of the multi-sized panels is as easy as an electric light fixture mounted on the surface, flush, placed in a suspended ceiling grid, or freely suspended. Painting, overspraying with water base acoustical material, or framing creates the desired aesthetic effect. Do no operate until dry.
Penetrable Surface Mounting (sheetrock) (Fig. 1)-(check for bag of hole plugs)
T-Bar Mounting (Fig. 2)
This is a description of a major benefit of using the product.
Inpenetrable Surface Mounting - RPD model (Concrete) (Fig. 3)
Each panel has been individually checked at the factory. However each panel should be field checked by measuring cold resistance for confirmation with label wattage. After panel installation, the entire circuit should be tested, to check the on-sight electrical work. Two methods of testing will be discussed in the following paragraphs.
Full Power Available - Apply rated voltage to the heater load circuit. Branch loads are to be read with a suitable amp meter. The amp meter value should be the same as that calculated for the heating load and, if the values agree, all panels are operating. If the values do not agree, installation should be re-checked. For physical check without a meter, it is only necessary to feel the panels. If they are warm but can only be touched for a few seconds, they are working.
Without Power Available - This check of the panel installation requires the use and knowledge of an ohmmeter. A resistance measurement is taken at the load circuit, with all other circuits isolated. This will give the total resistance of the heater load. Knowing the total heater load of the panel in watts and the heater rated voltage, a simple calculation will give the same values as that read on the ohm meter. (The same test procedure applies of an individual panel) Example: For a branch circuit of 1500 watts and panel rated voltage of 240, the resistance will be 38.4 ohms:
![]() |
| All sizes also available in 208 and 277 volt (other sizes and wattages available) | ||||||
| Model No. | Voltage | Watts | BTUH | Amperage | Size | Weight(lbs.) |
| Under Desk Heaters | ||||||
| 12UDH-4 | 120 | 100 | 341 | 0.8 | 11¾" x 23¾" x 1" | 3 |
| 22UDH-4 | 120 | 200 | 683 | 1.7 | 24¼" x 23¾ x 1" | 3 |
| Radiant Ceiling Panels NOTE: All Panel Frames have mounting holes except T-BAR | ||||||
| 22RP-2 | 240 | 200 | 682 | 0.8 | 24¼" x 23¾ x 1" | 6 |
| 22RP-4 | 120 | 200 | 682 | 1.7 | 24¼" x 23¾ x 1" | 6 |
| 22RP-2or4TBar | 120or240 | 200 | 682 | 0.8 or 1.7 | 23¾" x 23¾ x 1" | 6 |
| 23RP-2 | 240 | 300 | 1024 | 1.3 | 24¼" x 35¾ x 1" | 8 |
| 23RP-4 | 120 | 300 | 1024 | 2.5 | 24¼" x 35¾ x 1" | 8 |
| 24RP-2 | 240 | 400 | 1365 | 1.7 | 24¼" x 47¾ x 1" | 11 |
| 24RP-4 | 120 | 400 | 1365 | 3.3 | 24¼" x 47¾ x 1" | 11 |
| 24RP-2or4TBar | 120or240 | 400 | 1365 | 1.7 or 3.3 | 23¾" x 47¾ x 1" | 11 |
| 24RPH-2 or 4 | 120 or 240 | 500 | 1706 | 2.1 or 4.2 | 24¼" x 47¾ x 1" | 11 |
| 25RP-2 | 240 | 500 | 1706 | 2.1 | 24¼" x 59¾ x 1" | 13 |
| 25RP-4 | 120 | 500 | 1706 | 4.2 | 24¼" x 59¾ x 1" | 13 |
| 26RP-2 | 240 | 600 | 2047 | 2.5 | 24¼" x 68¾ x 1" | 15 |
| 26RPH-2 | 240 | 750 | 2560 | 3.1 | 24¼"x 68¾" x 1" | 15 |
| 26RP-4 | 120 | 600 | 2047 | 5.0 | 24¼" x 68¾" x 1" | 15 |
| 27RP-2 | 240 | 700 | 2388 | 2.9 | 24¼" x 83¾ x 1" | 17 |
| 27RP-4 | 120 | 700 | 2388 | 5.8 | 24¼" x 83¾ x 1" | 17 |
| 28RP-2 | 240 | 800 | 2730 | 3.3 | 24¼" x 95¾ x 1" | 19 |
| 28RPH-2 | 240 | 1000 | 3413 | 4.2 | 24¼" x 95¾ x 1" | 19 |
| 28RP-4 | 120 | 800 | 2730 | 6.7 | 24¼" x 95¾ x 1" | 19 |
| Bathroom Fan/light/nightlight package - complete: includes Decora switch/cover & thermostat | ||||||
| 22RPFL-2 or 4 | 240 or 120 | 200 | 682 | 0.8/1.7 | 24¼" x 35¾" x 1" | 7+25 |
| 23RPFL-2 or 4 | 240 or 120 | 300 | 1024 | 1.2/2.5 | 24¼" x 47¾" x 1" | 9+25 |
| 24RPFL-2 or 4 | 240 or 120 | 400 | 1365 | 1.7/3.3 | 24¼" x 59¾" x 1" | 12+25 |
| 25RPFL-2 or 4 | 240 or 120 | 500 | 1720 | 2.1/4.2 | 24¼" x 68¾" x 1" | 14+25 |
| 26RPFL-2 or 4 | 240 or 120 | 600 | 2082 | 2.5/5.0 | 24¼" x 83¾" x 1" | 17+25 |
| 27RPFL-2 or 4 | 240 or 120 | 700 | 2388 | 2.9/5.8 | 24¼" x 95¾" x 1" | 19+25 |
| ENERJOY THERMOSTATS | ||||||
| TSSHC-1 | ALL | LineVolt/Bimetal | White | 2¾" x 4½ x 1¾" | 1 | |
| TSSHC-1P | 120or240 | LV-Prog. - 7-day/24hr | Beige | 2¾" x 4½ x 1¾" | 1 | |
| TSSHC-1LV | 24 | Low volt non-mercury | Beige | 2¾" x 4½ x 1½" | 1 | |
| TSSHC-12S | ALL | 2 Circuit, 2 Stage line v. | Beige | 2 1/3" x 4½ x 1¾" | 1 | |
| TSSHC-2H | ALL | Hydraulic Line Voltage | Beige | 2¾" x 4½ x 1½" | 1 | |
| TSSHC-2D (1) | ALL | Air Diaphragm Line V. | White | 2¾" x 4½ x 1¾" | 1 | |
| TSSHC-3D | 120or240 | Digital Line Voltage | Ivory | 3¼" x 6¾" x 2¾" | 1 | |
| TSSHC-3DP (2) | 120 + 240 | LV Digital Progammable | Ivory | 5" x 5" x 1¾" | 1 | |
| TSSHC-3DP | 240 | LV Digital Progammable | Ivory | 3" x 5" x 1 ¾ " | 1 | |
| TSSHC-3BC | 240 | LV Programmable Bulb/Cap | Ivory | 2¾" x 4½ x 1½" | 1 | |
| TSSHC-3ILAS (3) | 120or240 | LV Electronic | White | 3¼" x 4½" x 1¾" | 1 | |
| TSSHC-3ILRS (3) | 120or240 | LV Electronic | White | 3¼" x 4½" x 1¾" | 1 | |
| (1) Range stops, Locking cover, Thermometer, All Thermostats fit single gang Electrical Box | ||||||
| (2) Proportional Control Feature | ||||||
| (3) Range stops and Indicator Light | ||||||
SSHC, Inc.
Copyright © 1998-2003 SSHC, Inc. All rights reserved.
Information in this document is subject to change without notice.
Characteristics of Radiant Heat |
Quick System Sizing |
Thermostats |
ENERJOY I - Specs |
Comparison of Enerjoy I & II |
Bathroom Comfort Center |
Contacting SSHC, Inc. |
SSHCINC Main URL