Quick System Sizing...
Design Guidelines
1) Determine panel size by selecting a balanced combination of Enerjoy Peopleheaters to cover 10% of the ceiling surface.
2) Design symmetrical heatmodule placement in the same way you locate lights to illuminate a room, recognizing areas of high heat loss and special comfort areas.
3) Take full advantage of the broad dispersion of radiant energy emanating at a 80° angle from the heatmodule surface. It is all right to over size[1] by using identical heatmodules to attain symmetry even though the sizing chart calls for unequal or smaller units.
Rules of Thumb:1) Select a geometrically pleasing design, while allowing a 2' to 4' setoff[2] from exterior walls and figuring approximately two times the setoff distance between Peopleheaters. 2) Use the following general specifications to determine watts per square foot (W/SF) of room area: Bath areas: 7 W/SF; Living room or corner offices: 6 W/SF; Dens, offices, dining rooms or corner bedrooms: 5W/SF; Kitchens or middle bedrooms: 4 W/SF. Above 7,000 degree days add 1 W/SF.
[1]The sizing increase or decrease determines cycle frequency- how quick the thermostat setpoint is satisfied.
[2]There is no set off restriction. Unnecessary heat loss is minimized
Enerjoy Peopleheater Selection
| Room (typical) | Size (feet) | Area (SQ.FT.) | New Construction (8' ceilings) |
Thermostat |
|---|---|---|---|---|
|
Closet/powder |
4 x 5 | 20-30 | 22RP or 22RPFL | 1 |
| Standard bath | 5 x 7 | 35-50 | 23RP, 24RP or 23RPFL | 1 |
| Large bath | 8 x 10 | 75-100 | 25RP or 25RPFL | 1 |
| Den/office | 8 x 10 | 75-100 | 24RP or 25RP | 1 |
| Corner bed | 12 x 12 | 130-160 | 28RP or 2-24RP | 1 |
| Middle bed | 12 x 12 | 130-160 | 26RP | 1 |
| Lg. Corner bed | 13 x 15 | 170-210 | 2-25RP or 2-26RP | 1 |
| Lg. Middle bed | 13 x 15 | 170-210 | 28RP or 2-24RP | 1 |
| Standard Kit. | 9 x 12 | 150-180 | 24RP | 1 |
| Lg. Kitchen | 11 x 15 | 150-18 | 26RP or 2-23RP | 1 |
| Stand. Dining | 8 x 12 | 90-120 | 25RP or 2-23RP | 1 |
| Lg. Dining | 12 x 14 | 150-190 | 28RP or 2-24RP | 1 |
| Stand. Living | 12 x 15 | 160-200 | 2-26RP | 1 |
| Lg. Living | 14 x 20 | 260-300 | 3-28RP | 1 |
| Wiring note: Existing 20 amp 120 volt lighting circuits may serve Enerjoy I Heatmodules. | ||||
| Insulation note: Insulate floor above basement or crawlspace. | ||||
Additional Guidelines:
Supplemental heating: basements and super-insulated houses- Use 1-24RP for each 100 sq. ft. of space--approx. 3-4 W/SF.
Cathedral ceilings or 10' ceilings:
For 12' peak (avg. 10') increase heat panel area by 25%. Ex.- Use 28RP instead of 26RP.
For 16' peak (avg. 12') increase heat panel size by 50%.
Split Levelbuildings- Add one watt per square foot.
Fireplaces, sliders or skylights- Add one watt per square foot.
TYPICAL ENERJOY® SIZING CHARTS
MODEL ENERGY CODE SPECIFICATIONS
OPERATIVE TEMPERATURE 70°F
ROOM DIMENSIONS 15 x 15 x 8
MIDDLE ROOM – 1 OUTSIDE WALL![]() |
ENERJOY SELECTION:
|
CORNER ROOM – 2 OUTSIDE WALLS![]() |
ENERJOY SELECTION:
|